Shrouds available in either Standard size (45" x 56") or Extended size (58" x 70")
Worker Decontamination: Standard MT-3 P.I.E. has hot and cold water reservoirs that are line fd into a shower head inside the units. Waste water drains into a holding tank under the work platform.
Unit Decontamination: Units are washed down and HEPA vacuumed. Heavy debris is passed through trap door into bag on the outside of the units.
HEPA Filtration: Standard units use minimum 1200 CFM exhaust fans with HEPA filters and two sets of pre-filters to trap 99.97% of particulate.
Negative Pressure: Manometer readings of minus 0.03 inches of water column relative to adjacent non-work areas are achieved inside these units.
Controlled Air Flow: The fan-powered controlled airflow allows for complete air changes every three seconds when the unit is raised to 12 feet. This flushing of air allows the unit to transform from a dirty, contaminated work area to a decontamination facility and clean room within minutes. This controlled airflow will not allow harmful dusts or microbes to escape outside the MT-3 P.I.E.